2008 Fleetwood Bounder Diesel problems: recalls, complaints and what to check
NHTSA has 8 recalls and 2 owner complaints on file for the 2008 Fleetwood Bounder Diesel. Here is what they are, what a technician checks for each kind of fault, and how to look one over before you buy it.
12 volt and 120 volt electrical: 3 recalls, 2 complaints
Recall 09V056000 (18/02/2009): ELECTRICAL SYSTEM:12V/24V/48V BATTERY:CABLES
FLEETWOOD IS RECALLING 3,782 MY 2006-2009 PROVIDENCE, EXCURSION, EXPEDITION, DISCOVERY AND BOULDER DIESEL MOTOR HOMES. THE BATTERY CABLE IS ROUTED TOO CLOSE TO A SHARP EDGE LOCATED ON TOP OF A SHELF INSTALLED OVER THE DRIVESHAFT.
Fix: DEALERS WILL RE-ROUTE THE CABLE AWAY FROM THE SHARP EDGE LOCATION. THIS SERVICE WILL BE PERFORMED FOR YOU FREE OF CHARGE. THE RECALL BEGAN ON MAY, 26 2009. OWNERS MAY CONTACT FLEETWOOD AT 800-509-3418.
Recall 08V013000 (10/01/2008): ELECTRICAL SYSTEM:WIRING
ON CERTAIN MOTOR HOMES EQUIPPED WITH A FIELD EFFECT TRANSISTOR (FET) BOARD BUILT BY MAGNUM ENERGY, INC., THE CIRCUITRY INSIDE CERTAIN INVERTERS CAN CAUSE AN INOPERATIVE CONDITION RESULTING IN OVERHEATING OF THE INVERTER.
Fix: DEALERS WILL INSPECT AND REPLACE THE INVERTER FREE OF CHARGE. THE RECALL BEGAN ON JANUARY 19, 2008. OWNERS MAY CONTACT FLEETWOOD AT 1-800-509-3418.
Recall 09V175000 (21/05/2009): ELECTRICAL SYSTEM:12V/24V/48V BATTERY:CABLES
FLEETWOOD IS RECALLING 311 MY 2008-2009 PROVIDENCE, EXCURSION, EXPEDITION, DISCOVERY AND BOUNDER DIESEL MOTOR HOME. THE BATTERY CABLE MAY BECOME DISLODGED AND COME IN CONTACT WITH THE DRIVER SHAFT CAUSING ENTANGLEMENT OR ABRASION TO THE BATTERY CABLE.
Fix: DEALERS WILL INSPECT AND REPLACE DAMAGE BATTERY CABLES AND SECURE THE BATTERY CABLE HARNESS ABOVE THE DRIVE SHAFT FREE OF CHARGE. THE RECALL IS EXPECTED TO BEGIN DURING JUNE 2009. OWNERS MAY CONTACT FLEETWOOD AT 1-800-509-3418.
What a tech checks: Voltage drop, grounds, the converter and the transfer switch. Melted shore-cord plugs and bad grounds cause most of the electrical complaints techs actually see. Before you buy: Battery at rest, converter output on shore power, GFCI test, every outlet.
12 V electrical lessons · 120 V and generator lessons · Wiring diagrams
Other: 3 recalls, 1 complaint
Recall 08V292000 (01/07/2008): EQUIPMENT:OTHER:LABELS
FLEETWOOD IS RECALLING 226 MY 2008-2009 AMERICAN ALLEGIANCE, AMERICAN EAGLE, AMERICAN HERITAGE, AMERICAN TRADITION, BOUNDER, BOUNDER DIESEL, DISCOVERY, EXCURSION, EXPEDITION, FIESTA LX, PACE ARROW, PROVIDENCE, REVOLUTION LE, SOUTHWIND, CLASS A MOTOR HOMES, AND ICON, JAMBOREE, JAMBOREE GT, JAMBOREE SPORT, PULSE, TIOGA, AND TIOGA RANGER CLASS C MOTOR HOMES. THESE MOTOR HOMES FAIL TO COMPLY WITH THE REQUIREMENTS OF THE CODE OF FEDERAL REGULATIONS, PART 567, 'CERTIFICATION.' THE OCCUPANT AND CARGO CARRYING CAPACITY WERE CALCULATED INCORRECTLY ALLOWING ADDITIONAL LOAD CARRYING CAPACITY.
Fix: FLEETWOOD WILL MAIL A CORRECTED FEDERAL CERTIFICATION LABEL ALONG WITH INSTALLATION INSTRUCTIONS TO THE AFFECTED MOTOR HOME OWNERS. OWNERS WHO DO NOT FEEL COMFORTABLE INSTALLING THIS LABEL CAN TAKE THEIR MOTOR HOME TO ANY FLEETWOOD DEALER AND THE DEALER WILL INSTALL THE LABEL FOR THEM. THE RECALL BEGAN ON JULY 28, 2008. OWNERS MAY CONTACT FLEETWOOD AT 1-800-509-3418.
Recall 07V503000 (25/10/2007): EQUIPMENT:RECREATIONAL VEHICLE/TRAILER
ON CERTAIN MOTOR HOMES, THE SLIDE-OUT ROOM MAY ACTIVATE WHILE TRAVELING, CAUSING THE OVERALL VEHICLE WIDTH TO INCREASE.
Fix: DEALERS WILL INSPECT AND IF NECESSARY, RELOCATE CERTAIN ELECTRICAL COMPONENTS AND SEAL ASSOCIATED COMPARTMENTS FROM THE ELEMENTS. THE RECALL BEGAN ON JANUARY 11, 2008. OWNERS MAY CONTACT FLEETWOOD AT 1-800-322-8216.
Recall 07V504000 (25/10/2007): EQUIPMENT:RECREATIONAL VEHICLE/TRAILER
ON CERTAIN MOTOR HOMES, THE SLIDE-OUT ROOM MAY ACTIVATE WHILE TRAVELING, CAUSING THE OVERALL VEHICLE WIDTH TO INCREASE. WATER CAN SHORT OUT THE ELECTRONIC CONTROL RELAY FOR THE SLIDE-OUT ROOM CONTROL MECHANISM.
Fix: DEALERS WILL INSPECT AND IF NECESSARY, RELOCATE CERTAIN ELECTRICAL COMPONENTS AND SEAL ASSOCIATED COMPARTMENTS FROM THE ELEMENTS. THE RECALL BEGAN ON JANUARY 11, 2008. OWNERS MAY CONTACT FLEETWOOD AT 1-800-322-8216.
Motorhome chassis: 1 recall
Recall 07V306000 (18/07/2007): STEERING
FREIGHTLINER IS RECALLING CERTAIN SCHOOL BUS CHASSIS, HEAVY TRUCKS, VAN CHASSIS, RV MOTORHOME CHASSIS MANUFACTURED FROM JANUARY 5 TO MAY 17, 2007, EQUIPPED WITH AXLE ALLIANCE COMPANY (AAC) FRONT AXLES. DURING THE FRONT AXLE ASSEMBLY, THE FASTENERS THAT ATTACH THE STEERING ARM OR TIE ROD ARMS TO THE SPINDLE MAY BE OVER OR UNDER TIGHTENED.
Fix: THOMAS BUILT WILL NOTIFY OWNERS, INSPECT THE FASTENERS, AND REPLACE THE STEERING ARM IF NECESSARY. THE RECALL BEGAN ON DECEMBER 21, 2007. OWNERS CAN CONTACT FREIGHTLINER AT 1-800-547-0712.
What a tech checks: The chassis (Ford, Freightliner, Mercedes, Ram) is serviced by the chassis maker's dealer, not the RV shop. RV techs handle the house, not the drivetrain. Before you buy: Chassis recalls are fixed free at the chassis maker's dealer.
Axles, brakes, suspension and hitch: 1 recall
Recall 08V269000 (17/06/2008): SUSPENSION
DAIMLER TRUCKS IS RECALLING 2,506 MY 2008 XC MOTOR HOME CHASSIS AND THOMAS BUILT HDX SCHOOL AND TRANSIT BUSES EQUIPPED WITH SAF-HOLLAND ADL SERIES REAR SUSPENSIONS. IN SOME INSTANCES THE TRANSVERSE BEAM WAS NOT PROPERLY WELDED WHICH COULD RESULT IN A FAILURE OF THE WELD.
Fix: DAIMLER TRUCKS IS WORKING WITH SAF-HOLLAND TO HAVE A VISUAL INSPECTION OF THE ADL TRANSVERSE BEAM PERFORMED. IF A WELD DEFECT IS IDENTIFIED, SAF-HOLLAND WILL PROVIDE A SERVICE REPLACEMENT KIT THAT CONTAINS A NEW TRANSVERSE BEAM, ALL NECESSARY INSTALLATION HARDWARE, BEAM REPLACEMENT, AND INSTRUCTIONS FREE OF CHARGE (PLEASE SEE 08E031). THE RECALL RECALL BEGAN ON SEPTEMBER 12, 2008 (THOMAS BUILT BUSES) AND OCTOBER 8, 2008. OWNERS MAY CONTACT SAF-HOLLAND AT 1-231-773-3271 OR DAIMLER TRUCKS AT 1-800-547-0712.
What a tech checks: Bearings, brake magnets, worn shackle bolts and bent axles. A trailer that wears tires on the inside edge or pulls to one side usually has an axle or suspension problem. Before you buy: Bolts tight, springs not flat, brakes apply with the breakaway pin pulled.
Chassis and towing lessons · Trailer guide
What owners reported to NHTSA
09/24/2009, ELECTRICAL SYSTEM: TL* THE CONTACT OWNS A 2008 FLEETWOOD BOUNDER DIESEL RV. THE CONTACT RECEIVED RECALL NOTIFICATION NUMBER 09V056000, ELECTRICAL SYSTEM BATTERY CABLES; HOWEVER, THE MANUFACTURER IS NO LONGER IN BUSINESS. THE LEGAL HEIR OF THE BUSINESS REFUSED TO HONOR THE REMEDY OUTLINED IN THE RECALL. THE CURRENT MILEAGE WAS 7,500. UPDATED 10/20/09 *CN
07/04/2023, ELECTRICAL SYSTEM,UNKNOWN OR OTHER: Magnum Energy Management System isn’t working properly. While charging House Batteries when connected to 50amp shore power it goes to fault stating overtemp and shuts house appliances down. Also when my VIN# is searched I receive results stating it’s a 2008 Fleetwood Diesel Expedition. I purchased this new from Camping World of Roanoke, VA. Can you verify the VIN to my Bounder?
Looking at a 2008 Fleetwood Bounder Diesel?
The Buyer's Check walks you through it on your phone: what to ask, the outside walk-around, water damage, every system on every power source, with the recalls above built in. You get a report that says what's a walk-away and what to negotiate on.
Checked against NHTSA 2026-10-23. Recall repairs are free at an authorized dealer. Complaints are owner reports to NHTSA and are not verified.