Voltage drop: the test that finds bad grounds

A bad connection can show 12.6V with nothing running and fall flat the second you turn the load on. Test it while it's working.

The short version

On the job

  1. Load on (lights, pump, blower). Red lead on the battery positive post, black on the positive at the far load. That's the positive-side drop.
  2. Then black on the battery negative post and red on the load's negative. That's the ground-side drop.
  3. Over 0.5 V on either side is too much. Now measure across each connection in that run: the one over 0.1 V is your fault.
  4. Fix it, retest under the same load.

Numbers

Shop tip

Dim lights at the back of the rig but bright up front? Voltage drop. Usually a ground.