Lippert Schwintek in-wall slide: two motors, one on each side, with a controller. The controller counts motor turns through hall sensors to keep both sides together. It needs a 30 A fuse at minimum.

Schwintek slide code RED 2

Battery dropout (fell below 6 V while running). The battery or wiring is too weak for the load. Charge, fix voltage drop, test the battery under load.

Schwintek slide code RED 3

Low battery (under 8 V at start). Charge the battery. Check the supply wire and ground.

Schwintek slide code RED 4

High battery (over 18 V). Check the charger or converter. Disconnect extra chargers.

Schwintek slide code RED 5

Excessive motor current. Binding, a stall, or a failed motor. One side stalling again and again points to that motor or its gear.

Schwintek slide code RED 6

Motor short circuit. The motor or its wiring is shorted. Unplug one motor at a time to find which.

Schwintek slide code RED 8

Hall signal not present. The sensor is not sending counts. Usually the wiring or plug to that motor.

Schwintek slide code RED 9

Hall power shorted to ground. Short in the hall power wire. Usually wiring or plug.