Sort the complaint first: won't crank, cranks but won't start, starts then dies, or runs but no power.

The short version

On the job

  1. Fuel above a quarter tank. The generator pickup is higher than the engine's.
  2. Read the code: STOP/PRIME once, count blinks (tens, pause, ones). Code 36 engine stopped, 4 over crank, 32 slow crank, 2 oil, 13/15 under voltage or frequency = overload.
  3. Fuel at the carb (crack the line while cranking), spark with an inline tester, then a short shot of starting fluid: fires and dies means the carb.
  4. Oil level and viscosity for the weather. Battery 450 CCA minimum, clean cables.
  5. Run it under load 30 minutes a month.

Numbers

Shop tip

On motorhomes, the generator's fuel pickup sits higher in the tank. Under about a quarter tank it can't get fuel. That's by design so it can't run the coach dry.