Safe-T-Alert LP and CO detector fault codes
Press TEST during warm-up or normal operation: red flashes and the alarm sounds. Test weekly, before each trip and after storage. Press TEST-MUTE during an alarm to silence it for 2 minutes; it will not mute a malfunction.
Safe-T-Alert: Solid green
Normal. Nothing to do.
Safe-T-Alert: Flashing yellow
Warm-up after power is applied. Wait a minute or two for solid green.
Safe-T-Alert: Flashing red, continuous tone
Gas alarm. Shut the cylinders, ventilate, no switches or flames. Then leak test the LP system. False alarms: hairspray, cleaners, a new carpet, low battery under about 10 V, a contaminated sensor after storage.
Safe-T-Alert: Flashing red, beep every 30 s
Alarm during a mute cycle. Mute was pressed. The alarm beeps every 30 s until gas levels drop, then flashes green until the mute cycle ends (2 minutes).
Safe-T-Alert: Red and green alternating, two beeps every 15 s
Malfunction. Sensor failed or contaminated. Mute does nothing. Check 12V at the detector (7 to 16 VDC), then replace the detector.
Safe-T-Alert: Chirp with low coach voltage
Low voltage. Charge the battery; most 12V detectors need 7 V or more. Find the drain.
Safe-T-Alert: Chirp, detector 5 to 7 years old
End of life. Replace it. The install or manufacture date is on the back.