Safe-T-Alert LP and CO detector fault codes

Press TEST during warm-up or normal operation: red flashes and the alarm sounds. Test weekly, before each trip and after storage. Press TEST-MUTE during an alarm to silence it for 2 minutes; it will not mute a malfunction.

Safe-T-Alert: Solid green

Normal. Nothing to do.

Safe-T-Alert: Flashing yellow

Warm-up after power is applied. Wait a minute or two for solid green.

Safe-T-Alert: Flashing red, continuous tone

Gas alarm. Shut the cylinders, ventilate, no switches or flames. Then leak test the LP system. False alarms: hairspray, cleaners, a new carpet, low battery under about 10 V, a contaminated sensor after storage.

Safe-T-Alert: Flashing red, beep every 30 s

Alarm during a mute cycle. Mute was pressed. The alarm beeps every 30 s until gas levels drop, then flashes green until the mute cycle ends (2 minutes).

Safe-T-Alert: Red and green alternating, two beeps every 15 s

Malfunction. Sensor failed or contaminated. Mute does nothing. Check 12V at the detector (7 to 16 VDC), then replace the detector.

Safe-T-Alert: Chirp with low coach voltage

Low voltage. Charge the battery; most 12V detectors need 7 V or more. Find the drain.

Safe-T-Alert: Chirp, detector 5 to 7 years old

End of life. Replace it. The install or manufacture date is on the back.

Learn the system

Practice it on a service call

Guided diagnosis

Full field guide: Safe-T-Alert LP and CO detector

Codes come from the maker manuals and public service sheets. Your model's own chart always wins, and LP and 120 volt work belongs to a qualified technician.