LP, CO and smoke alarms

Alarms that chirp or go off are a top service complaint. Never assume it's a false alarm until you've checked.

The short version

On the job

  1. LP alarm: cylinders off, ventilate, no switches. Then leak test. Then check the detector's date and 12V.
  2. Safe-T-Alert: green normal, flashing red + tone alarm, red/green alternating + two beeps every 15 s = malfunction, flashing yellow = warm-up.
  3. Chirp every 30 to 60 s on CO or smoke: battery or end of life. Replace the battery, then the unit if it keeps chirping.
  4. CO alarm: everyone out, fresh air, generator and gas appliances off, find the source with a meter.

Numbers

Shop tip

Check the date on every detector during service. Expired detectors are a liability.