Fault codes / 12V compressor fridge

12V compressor fridge controller fault codes

A small DC compressor with an electronic controller, a condenser fan, and a thermostat sensor. It runs on 12V (some also 120V). It is fast to cool but fussy about voltage.

12V compressor fridge: 1 blink

Battery protection cutout. Voltage too low. Charge the battery and fix voltage drop.

12V compressor fridge: 2 blinks

Fan overload. Check the condenser fan for jams or a short.

12V compressor fridge: 3 blinks

Compressor failed to start. Low voltage, locked compressor, or a pressure not equalized. Wait 5 minutes and retry. Check wiring.

12V compressor fridge: 4 blinks

Minimum motor speed fault. Often a restricted or failing compressor, or low voltage.

12V compressor fridge: 5 blinks

Controller overtemperature. Poor ventilation around the controller or compressor. Clear the airflow.

Learn the system

Practice it on a service call

Guided diagnosis

Full field guide: 12V compressor fridge controller

Codes come from the maker manuals and public service sheets. Your model's own chart always wins, and LP and 120 volt work belongs to a qualified technician.