Absorption fridges (gas/electric)

These cool with heat. If it cools on one mode but not the other, the cooling unit is fine and you're chasing the bad heat source.

The short version

On the job

  1. Level first: a level on the freezer floor, 3° side to side, 6° front to back max.
  2. Dollar bill test both gaskets. Frost thickest where the gasket leaks.
  3. Feel the boiler and absorber from the outside vent. Very hot boiler and no frost on the fins = no circulation (level) or a dying unit.
  4. Look for yellow powder, ammonia smell, wet boiler insulation. Any of those: do not run it, replace the cooling unit.
  5. Then the heat source: 11 in WC and a blue flame on gas; 108 to 132 V and element ohms on electric.

Numbers

Shop tip

Feel the back. Boiler area hot but the box warm = cooling unit problem. Boiler cold = heat source problem.

Try it on a service call

Put the lesson to work on a hands-on troubleshooting case.

Keep going on refrigerators

Learn it

Prove it

See it in 3D

Codes and specs

On the job