rigprobe.com

Fault codes / Dometic fridge

Dometic absorption fridge fault codes

The E-codes below are for the RM1350 series (4-door Elite style, including RM1350SL). Other Dometic models use different codes or indicator lights. Match the model label first.

Dometic fridge code E0

Display not talking to the power module. Check the display cable and plug, and 12V at the module. Reseat connectors. Replace the display or module if it persists.

Dometic fridge code E1

LP operation hardware fault. The LP system has a fault. See if AC mode still works. Service the LP gas valve, ignition or control. Do not skip safety checks.

Dometic fridge code E2

Temperature sensor or its circuit. Check the sensor plug and wiring. Measure the sensor ohms. Replace if open or shorted.

Dometic fridge code E3

Cooling unit malfunction. This is not the LP ignition code. Check heat on both LP and AC, ventilation and level. Run the full-run test. May need a cooling unit.

Dometic fridge code E4

DC voltage out of range. Check the battery, charger or converter, and voltage drop on the 12V supply to the fridge.

Dometic fridge: Flashing LP

LP ignition did not finish. After a tank change or long storage, turn the fridge off and on at the front. Bleed air from the line. If it returns, check gas pressure, burner, electrode and sensor.

Learn the system

Practice it on a service call

Guided diagnosis

Full field guide: Dometic absorption fridge

Codes come from the maker manuals and public service sheets. Your model's own chart always wins, and LP and 120 volt work belongs to a qualified technician.