Girard GSWH-2 code E1
What it means: Ignition failed or flame lost at start.
What to check
Gas valve open, tank has LP, igniter gap and condition, debris on the burner, low gas pressure, air in the lines. Test with a manometer while it fires.
Learn the system
Practice it on a service call
Guided diagnosis
Other Girard GSWH-2 codes
- Girard GSWH-2 code E0 Outlet water thermistor open or shorted
- Girard GSWH-2 code E2 Flame lost while running
- Girard GSWH-2 code E3 Eco (high-limit) switch is open
- Girard GSWH-2 code E4 Inlet water thermistor open or shorted
- Girard GSWH-2 code E5 Blower fault
- Girard GSWH-2 code E6 Outlet water over 140 F for 3 seconds
- Girard GSWH-2 code E7 Linear gas valve open circuit
- Girard GSWH-2 code E8 Air pressure switch fault
- Girard GSWH-2 code E9 Flame sensed before ignition or a short
- Girard GSWH-2 code Fd Freeze protection is active
- Girard GSWH-2 code En Run timer ended
Full field guide: Girard GSWH-2 tankless water heater
Codes come from the maker manuals and public service sheets. Your model's own chart always wins, and LP and 120 volt work belongs to a qualified technician.