Fault codes / Girard GSWH-2 / En
Girard GSWH-2 code En
What it means: Run timer ended.
What to check
The 20 minute run timer expired. Close and reopen the tap to restart.
Learn the system
Practice it on a service call
Guided diagnosis
Other Girard GSWH-2 codes
- Girard GSWH-2 code E0 Outlet water thermistor open or shorted
- Girard GSWH-2 code E1 Ignition failed or flame lost at start
- Girard GSWH-2 code E2 Flame lost while running
- Girard GSWH-2 code E3 Eco (high-limit) switch is open
- Girard GSWH-2 code E4 Inlet water thermistor open or shorted
- Girard GSWH-2 code E5 Blower fault
- Girard GSWH-2 code E6 Outlet water over 140 F for 3 seconds
- Girard GSWH-2 code E7 Linear gas valve open circuit
- Girard GSWH-2 code E8 Air pressure switch fault
- Girard GSWH-2 code E9 Flame sensed before ignition or a short
- Girard GSWH-2 code Fd Freeze protection is active
Full field guide: Girard GSWH-2 tankless water heater
Codes come from the maker manuals and public service sheets. Your model's own chart always wins, and LP and 120 volt work belongs to a qualified technician.