Fault codes / SeeLevel tank monitor
SeeLevel II and Lippert MyRV tank monitor fault codes
Sender panels are self-adhesive circuit boards stuck to the OUTSIDE of the tank. They read the level through the tank wall and auto-calibrate to the length they are cut. Each sender talks to the display over a 2-wire cable with error-checked data, so the display can tell you what is wrong.
SeeLevel tank monitor code OPn
Open. Sender unresponsive or open wiring. On LPG: open wiring or bad resistance sender.
SeeLevel tank monitor code Sht
Short. Shorted sender or wiring. (LPG short reads zero all the time.)
SeeLevel tank monitor code Err
Data error. Bad data, damaged wiring or electrical interference.
SeeLevel tank monitor: ntP / nbo
Stacked senders. ntP = no top sender received. nbo = no bottom sender received. Both missing = OPn.
SeeLevel tank monitor: bot / toP / sin
Single sender setup. Shows how the single sender is programmed. Informational.
Learn the system
Practice it on a service call
Guided diagnosis
Full field guide: SeeLevel II and Lippert MyRV tank monitor
Codes come from the maker manuals and public service sheets. Your model's own chart always wins, and LP and 120 volt work belongs to a qualified technician.